CFP Standard 2 Zone Conventional Fire Alarm Panel

Call for Price

Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.

Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.

A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.

Optional repeaters and relay expansion boards also available.

Category: Brand:
ORDER NOW
Approvals / Certifications Certified to EN54-2 & 4 by the LPCB, Certified to EN54-13 by Kiwa Telefication
Mains Supply 230V 50/60Hz
Mains Rated Current 350mA maximum
Internal Power Supply 19V–28.5V (27V nominal). Ripple 7V maximum (battery fault)
Total Output Current Limited To 1.5A @ 230Vac (ImaxA eq 146mA)
Quiescent Current 25mA (mains failed, internal sounder active, PSU & gen fault LED lit)
Max Battery Size and Type 2 × 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah
No. of Detector Zone Circuits 2 (Max. length per circuit is 500m)
Call Point Resistor Value 470 to 680Ω
Max Devices per Detector Zone 25 detectors (or 32 detectors/manual call points combined)
No. of Conventional Sounder Circuits 4 (Max. length per circuit is 500m)
EOL Resistor Value 6800Ω 5% Tol. 0/25W (blue, grey, red, gold)
Alarm Voltage 27V max, 20V min (final battery voltage)
Max Sounder Output Current 4 × 200mA (800mA total)
Auxiliary Relays Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover.
Max. switch current 1A; Max. switch voltage 30Vdc
Open Collector Outputs Two: (1) Reset; (2) Remote. Max. sink current 30mA
Other Outputs 24V Aux. Power (protected by resettable fuse, 100mA min. hold current)
Auxiliary Inputs Two: Class Change & Alert. Connect to 0V to trigger, max input 27V
Engineer (AL3) Functions Coincidence, Walk Test, Delays, Non-latching zones, Sounder resound
Expansion Connections Optional network driver cards, relay output cards, EN54-13 boards
Product Dimensions (mm) 380 W × 235 H × 96 D (Flush cut-out: 367 × 220 × 75)
Construction & Finish Plastic lid and base; RAL7035 textured
IP Rating IP30
Weight 1.75kg (without batteries)
Operating Conditions / Temperature -5°C to +40°C, Max relative humidity 95%
  • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
  • Manufactured by C-TEC in the UK.
  • Two detector zone circuits.
  • Four conventional sounder circuits*
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
  • Two on-board relays (Fire and Fault).
  • Two open-collector outputs (Remote and Reset).
  • ‘Class change’ and alert inputs.
  • Installer-friendly design.
  • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
  • Low 25mA quiescent current.
  • Multiple indicators.
  • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system) and optional CFP relay boards.
  • Space for two x 12V 3.3Ah VRLA batteries.
  • Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices.