UTP CAT6 Cable

34,500.00

Avaibility: In Stock
Categories: ,

PFM920I-6U-C

  • 305 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible   with one cable
  • High-purity oxygen-free copper conductor material
  • Customized PVC outer sheath; CE CPR Eca flame retardant class  certified
  • 10-year warranty

Conductor

Material Oxygen free copper (99.97% purity)
Diameter 0.57 mm ± 0.01 mm
American Wire Gauge 23AWG

Insulation

Material HDPE
Min. Average Thickness 0.21 mm
Diameter 1.0mm±0.1mm
Color (4 Pairs) Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

Separator

Material PE
Specification Translucent 4.5 × 0.4 mm
Rip Cord
Material Polyester
Specification 500D

Sheath

Material PVC
Min. Average Thickness 0.5 mm
Diameter 6.3 mm ± 0.3 mm
Color White

Electrical

Max. DC Resistance of a Single Conductor 7.5Ω/100 m
Min. Insulation Resistance 5000MΩ·km
Max. DC Resistance Unbalance 2% (pair intra), 4% (pairs inter)
Dielectric Strength No breakdown with 1KV DC for 1 min

Transmission

Characteristic Impedance 100 ± 15Ω
Near End Cross Talk ≥39.30 dB/100 m@250 MHz
Max. Attenuation 33 dB/100 m@250 MHz
Return Loss ≥17.3 dB/100 m@250 MHz

Mechanical

Tensile Strength Sheath≥9 MPa, insulation≥16 MPa
Elongation at Break Sheath≥100%, insulation≥100%
Installation Bending Radius >8 times of outer cable diameter
Conductor Elongation at Break ≥8%

Environmental

Shrinkage of Insulation ≤5%
Color Migration Resistance of Insulation No migration
Sheath Tensile Strength and Elongation at Break after Aging ≥6.3 MPa, ≥100%
Low Temperature Bending Test No cracking after the test
Heat Shock Test No cracking after the test
Operating Temperature –20°C to +60°C (–4°F to 140°F)
Installation Temperature 0°C to +50°C (32°F to 122°F)
Storage Temperature and Humidity –10°C to +40°C (14°F to 104°F), <60% (RH)

Security

Vertical Fire Propagation Test Comply with IEC 60332-1-2

Packaging

Cable Length 305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
Inner Carton Dimensions 416.0 mm × 412.0 mm × 220.0 mm (16.38″ × 16.22″ × 8.66″) (L × W × H)
Packaging Method 305.0 m (1000.66 ft) a carton, one master carton with 2 inner cartons
Net Weight ≥11.9 kg (26.24 lb)
Gross Weight ≥12.9 kg (28.44 lb)

Compliance

Executive Standards ISO/IEC 11801-1-2017, IEC 61156-5-2009
Certification
Certification CPR Eca
Transmission Characteristics

(100 m at 20°C) (328.08 ft at 68°F)

Frequency (MHz) Phase delay ≤ ns IL ≤ dB TCL≥ dB﹡ EL TCTL≥ dB﹡ NEXT ≥ dB PS NEXT ≥ dB
1 n/s n/s 50.0 35.0 n/s n/s
4 552.0 3.8 44.0 23.0 66.3 63.3
8 547.0 5.4 41.0 16.9 61.8 58.8
10 545.0 6.0 40.0 15.0 60.3 57.3
16 543.0 7.6 38.0 10.9 57.2 54.2
20 542.0 8.5 37.0 9.0 55.8 52.8
25 541.0 9.6 36.0 7.0 54.3 51.3
30﹡ 540.6 10.5 35.2 5.5 53.1 50.1
31.25 540.0 10.7 35.1 n/s 52.9 49.9
62.5 539.0 15.5 32.0 n/s 48.4 45.4
100 538.0 19.9 30.0 n/s 45.3 42.3
200 537.0 29.1 27.0 n/s 40.8 37.8
250 536.0 33.0 26.0 n/s 39.3 36.3
Frequency (MHz) EL FEXT ≥ dB PS EL FEXT ≥ dB RL ≥ dB Delay skew ≤ ns Zc(Ω)
1 n/s n/s n/s n/s n/s
4 56.0 53.0 23.0 45.0 100±15
8 49.9 46.9 24.5
10 48.0 45.0 25.0
16 43.9 40.9 25.0
20 42.0 39.0 25.0
25 40.0 37.0 24.3
30﹡ 38.5 35.5 23.8
31.25 38.1 35.1 23.6
62.5 32.1 29.1 21.5
100 28.0 25.0 20.1
200 22.0 19.0 18.0
250 20.0 17.0 17.3
Note:

Executive standard for the above parameters: ISO/IEC 11801-1-2017″n/s”=Not Specified

“﹡”=Unless otherwise customer stated the test results default to not shown in test report but comply with standard