UTP CAT6 Cable

29,800.00

Avaibility: In Stock
Categories: ,

PFM920I-6U-U

  • 305 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible  with one cable
  • High-purity oxygen-free copper conductor
  • Customized PVC outer sheath; ANSI UL CM flame retardant class certified
  • 10-year warranty

Conductor

Material Oxygen free copper (99.97% purity)
Diameter 0.57mm ± 0.01 mm
American Wire Gauge 23AWG

Insulation

Material HDPE
Min. Average Thickness 0.21 mm
Diameter 1.0 mm ± 0.1 mm
Color (4 Pairs) Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

Separator

Material PE
Specification Translucent 4.5 × 0.4 mm
Rip Cord
Material Polyester
Specification 500D

Sheath

Material PVC
Min. Average Thickness 0.5 mm
Diameter 6.3 mm ± 0.3 mm
Color White

Electrical

Max. DC Resistance of a Single Conductor 7.5Ω/100 m
Min. Insulation Resistance 5000MΩ·km
Max. DC Resistance Unbalance 5% (pair intra)
Dielectric Strength No breakdown with 2.5KV DC for 2 seconds

Transmission

Characteristic Impedance 100 ± 15Ω
Near End Cross Talk ≥38.3 dB/100 m@250 MHz
Max. Attenuation 32.8 dB/100 m@250 MHz
Return Loss ≥17.3 dB/100 m@250 MHz

Mechanical

Tensile Strength Sheath≥13.8 MPa, insulation≥16.5 MPa
Elongation at Break Sheath≥100%, insulation≥300%
Installation Bending Radius >8 times of outer cable diameter
Conductor Elongation at Break ≥20%

Environmental

Shrinkage of Insulation ≤6%
Color Migration Resistance of Insulation No migration
Sheath Tensile Strength and Elongation at Break after Aging ≥11.73 MPa, ≥50%
Low Temperature Bending Test No cracking after the test
Heat Shock Test No cracking after the test
Operation Temperature –20°C to +60°C (–4°F to 140°F)
Installation Temperature 0°C to +50°C (32°F to 122°F)
Storage Temperature and Humidity –10°C to +40°C (14°F to 104°F), <60% (RH)

Security

Vertical Fire Propagation Test Comply with UL1685(without smoke measurements)

Packaging

Cable Length 305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
Inner Carton Dimensions 416.0 mm × 412.0 mm × 220.0 mm (16.38″ × 16.22″ × 8.66″) (L × W × H)
Packaging Method 305.0 m (1000.66 ft) a carton, one master carton with 2 inner cartons
Net Weight ≥11.9 kg (26.24 lb)
Gross Weight ≥12.9 kg (28.44 lb)

Compliance

Executive Standards ANSI/TIA 568-C.2-2009, UL444-2008

Certification

Certification UL CM
Transmission Characteristics

(100 m at 20°C) (328.08 ft at 68°F)

Frequency (MHz) Phase delay ≤ ns IL≤ dB TCL≥ dB﹡ EL TCTL≥ dB﹡ NEXT ≥ dB PS NEXT ≥ dB
1 570 2.0 40.0 35.0 74.3 72.3
4 552 3.8 40.0 23.0 65.3 63.3
8 547 5.3 40.0 16.9 60.8 58.8
10 545 6.0 40.0 15.0 59.3 57.3
16 543 7.6 38.0 10.9 56.2 54.2
20 542 8.5 37.0 9.0 54.8 52.8
25 541 9.5 36.0 7.0 53.3 51.3
30﹡ 540.6 10.4 35.2 5.5 53.1 50.1
31.25 540 10.7 35.1 n/s 51.9 49.9
62.5 539 15.4 32.0 n/s 47.4 45.4
100 538 19.8 30.0 n/s 44.3 42.3
200 537 29.0 27.0 n/s 39.8 37.8
250 536 32.8 26.0 n/s 38.3 36.3
Frequency (MHz) ACRF ≥ dB PS ACRF ≥ dB RL ≥ dB Delay skew ≤ ns Zc(Ω)
1 67.8 64.8 20.0 45.0 100±15
4 55.8 52.8 23.0
8 49.7 46.7 24.5
10 47.8 44.8 25.0
16 43.7 40.7 25.0
20 41.8 38.8 25.0
25 39.8 36.8 24.3
30﹡ 38.3 35.3 23.8
31.25 37.9 34.9 23.6
62.5 31.9 28.9 21.5
100 27.8 24.8 20.1
200 21.8 18.8 18.0
250 19.8 16.8 17.3
Note:

Executive standard for the above parameters: ANSI/TIA-568-C.2-2009

“n/s”=Not Specified

“﹡”=Unless otherwise customer stated the test results default to not shown in test report but comply with standard